SMARTTILE · DEVICEAUTOMATE™ · RUCKUS (COMMSCOPE)

RUCKUS, read through the controller you already have

Unleashed, SmartZone / vSZ or RUCKUS One — one read-only connection gives SmartTile every access point and ICX switch with its status, clients, radios and alarms, configuration backups and firmware advisories, next to the rest of the network. Connected per company.

SmartTile integrates with
RUCKUS access points (R / T / H series) and ICX switches through the system that manages them: Unleashed (the controller on the master AP, signed in like its dashboard), SmartZone / Virtual SmartZone (the public API on port 8443 with a read-only administrator) or RUCKUS One (the cloud, with an application token for your tenant).
How SmartTile automates it
SmartTile's agent reads each connection every 5 minutes — device list, status, clients, radios, alarms, identity — and stores it; the controller's verdict decides each imported device's UP / DOWN with state history, alerts and tickets; Config Backups, FirmwareAutomate advisories, AccessAutomate, Network Discovery and a Workflow trigger each have their own switch per connection.
Category
DeviceDeviceAutomate™

A RUCKUS access point watched by ping alone says up or down and nothing else — and an AP on a private address behind the firewall often cannot be pinged at all. The controller already knows everything: which APs are up, who is connected, how busy each radio is, which alarms are open. SmartTile reads that controller — Unleashed, SmartZone / vSZ or RUCKUS One — and never changes a setting, reboots a device or pushes firmware. It ships switched off and is connected per company.

What the RUCKUS connection turns on

Every AP and switch

Access points and ICX switches the controller manages, with model, serial, firmware, MAC, IP, zone / venue and group — written to the device record through the shared identity writer, never over a value a person typed.

UP / DOWN from the controller

Online → UP, offline → DOWN every 5 minutes, with state history, the client alert and the ITSM ticket like any outage. A device the controller stops listing is DOWN after three polls; a controller SmartTile cannot reach turns its devices UNKNOWN — never “all up”.

Clients, radios, throughput

Clients per band, channel utilisation, transmit power and throughput stored every poll for the RUCKUS window, Device Health thresholds and chart alerts; every Wi-Fi client with its IP, hostname, OS and SSID.

Alarms as reasons

The controller's alarms are stored against the device they name, so Live Network Status reads “Alerting · AP lost heartbeat” — never “see the RUCKUS console”.

Configuration backups

The configuration the controller holds for each AP — its record, zone / venue and WLANs — read over the API with secrets redacted, saved, hashed and diffed in Config Backups like every other vendor.

Firmware advisories

SmartZone: the newest AP firmware the zone can run on the same train, from the controller's own list. Unleashed: SmartChoice's release table. SmartTile never installs it.

AccessAutomate + Discovery

Administrator sign-ins, failed sign-ins and changes from the controller's event log; Network Discovery lists every RUCKUS AP, its LLDP neighbours and its clients in the SmartTile Auto Discovery box.

Workflows

A Workflow trigger, “A RUCKUS access point or switch reports a problem”, fires once per problem — offline, flagged, config not synced, a saturated radio, controller unreachable — never per poll.

What it takes — the change request

  1. Unleashed. Find the management IP (the master AP you open the dashboard at). Unleashed has one admin login — keep it in SmartTile only. Reach it over the site VPN or allow HTTPS from SmartTile's agent 157.245.117.9.
  2. SmartZone / vSZ. Administration → Admins & Roles → Administrators → Create a Read-Only administrator (smarttile-ro). Allow HTTPS 8443 from 157.245.117.9.
  3. RUCKUS One. Administration → Account Management → Settings → Application Tokens → Add: name “SmartTile”, role Read Only; copy the Client ID, Client Secret (shown once) and Tenant ID; note your region.
  4. In SmartTile. DeviceAutomate → RUCKUS → Add connection: pick the platform, enter the address and login (or the token), Test, Save, Sync now, then Preview → Import the devices to their location (online devices only, by default).
No agent, no change to the controller's configuration, no firmware push. Remove the login or token and access ends.
SwitchDefault
Platform switch (SmartChoice, Engine Safety) + kill switchOff until switched on.
Per connection: Active (the company's switch)On when saved; a company admin can switch it off at any time.
Alarms · Config Backups · AccessAutomateOn.
FirmwareAutomate advisories · Workflow eventsOff — each its own platform switch and a preflight that says what will be raised.
Only import online devicesTicked. Nothing is ever imported on its own.
SmartChoice · SmartTile DeviceAutomate™ — RUCKUS (CommScope)Page 1 of 2
SMARTTILE · DEVICEAUTOMATE™ · RUCKUS (COMMSCOPE) — SECURITY, WHAT SMARTTILE ASKS EACH PLATFORM, AND WHAT IS STILL BEING PROVEN

Security posture, for the change board

Read-only by design

SmartZone: session + reads. Unleashed: getstat / getconf only — never setconf, reboot or restore. RUCKUS One: GET / query only. Every session is closed when done.

Secret encrypted, never shown

The password or client secret is sealed with AES-256-GCM to its own connection row the moment it is saved; the API returns only “secret set”; the audit row lists which fields changed, never a value. WLAN passphrases are redacted before anything is stored.

Certificate pinned

Test captures the controller's certificate fingerprint. A different certificate is refused before the password is sent. Or require a CA-issued certificate.

Multi-tenant and audited

Connections are company rows; every route is checked against the caller's companies; devices import only to a location of the same company; every save, sync, import and Lab run is in the transaction log.

Exactly what SmartTile asks

GET/wsg/api/public/apiInfo · controller · rkszones · …/wlans · …/apFirmwareSmartZone: versions, controller, zones, WLANs, AP firmware the zone can run
POST/wsg/api/public/vX/session · query/ap · query/switch · query/client · query/alarm · query/eventSmartZone: sign in (DELETE to sign out) · APs · ICX switches · clients · alarms · administrator events
POST/admin/login.jsp · /admin/_cmdstat.jsp (getstat stamgr ap/client · getconf system/wlansvc-list · getstat eventd)Unleashed: sign in like the dashboard · APs, clients, system, WLANs, alarms — read calls only
POST · GET/oauth2/token/{tenant} · /venues · /venues/aps/query · /venues/switches/query · /clients/query · /alarms/query · /activitiesRUCKUS One: token · venues · APs · switches · clients · alarms · administrator activity

Common objections

ObjectionAnswer
“Our APs are on private addresses.”They do not need to be reachable. SmartTile reads the controller; the APs' status, clients and radios come from it.
“Will SmartTile change anything on the controller?”No. Every call is a read; the only writes are into SmartTile. The Lab proves the round trip and shows every call.
“Will it push firmware?”No. SmartTile raises an advisory (SmartZone zone list or SmartChoice's Unleashed table) and verifies the running version after your engineer upgrades. RUCKUS One upgrades itself.
“What about the SmartZone backup file?”The public API does not expose it; SmartTile backs up the configuration the controller holds for each AP and says so plainly. The .bak stays a console download.
One read-only RUCKUS connection — and every access point reports down like the rest of your network.
SmartChoice · smarttile.smartchoiceus.com · (800) 217-3096, 24×7 · verified 2026-11-03Page 2 of 2