SMARTTILE · DEVICEAUTOMATE™ · SNMP v2c / v3

Any SNMP agent, read like a native integration

Switches, firewalls, UPS units, servers and NAS boxes with no vendor API still answer SNMP. SmartTile polls them read-only over v2c or v3 — reachability, interface traffic and errors, identity, health sensors — and turns a silent agent into a DOWN with a ticket in the IT Service Management (ITSM) system your team already uses.

SmartTile integrates with
Any SNMP v2c or SNMPv3 agent (noAuthNoPriv / authNoPriv / authPriv; MD5 or SHA-1…SHA-512 auth, DES / AES-128 / AES-256 privacy) — polled directly, from the site tunnel address, or through an SSH jump host.
How SmartTile automates it
The monitoring engine GETs sysUpTime and every discovered interface's status, 64-bit traffic and error counters every 7–9 min; identity is read every 6 h and written to the device record. An SNMP-only device that stops answering goes DOWN and follows the normal alert → ticket path.
Category
DeviceDeviceAutomate™

A device you can only reach by SNMP is usually watched by ping alone — up or down, nothing else. With the community string or v3 user saved on the device, SmartTile asks the agent the questions a NOC asks: is it answering, what is it, how busy are its links, is it healthy? Every request is a read (GET / GETBULK / walk). SmartTile never issues an SNMP SET.

What SNMP turns on

Reachability from the agent

An SNMP_Availability check (sysUpTime) on every SNMP device. For a device with ping turned off, that SNMP GET is the host check — three failed polls and it is DOWN.

Interface traffic and errors

Discover Interfaces walks the ifTable once; each port then gets oper-status, ifHCIn/OutOctets + ifSpeed, and in/out errors and discards. The Bandwidth button graphs per-interface Mbps from 24 h to 1 year.

Identity that fills itself

Every 6 h: sysDescr, sysObjectID, sysName, uptime, and ENTITY-MIB chassis rows — vendor, model, serial and firmware for every stack member. Shown in Edit Device as “Detected via SNMP · 2 h ago”; a value typed by a person is never overwritten.

Health sensors

The Device Health panel reads HOST-RESOURCES (CPU, memory, disk), ENTITY-SENSOR (temperature, fans, PSUs) and UPS-MIB (charge, runtime, load, self-test), plus vendor OIDs chosen from the Device Catalog.

Vendor OID profiles

FortiGate, Cisco IOS / ASA, Palo Alto, SonicWall, Juniper, MikroTik, APC, Synology, Aruba, Dell and more — every vendor OID carries a published-MIB citation. A vendor we could not verify gets standard MIBs only, and says so.

Bandwidth-threshold tickets

Opt a circuit in with the Bandwidth Trigger: its interface counters are read over SNMP every 60 s and a sustained breach (“over X Mbps for N minutes”) opens a ticket; the first clean sample closes it.

A badge that tells the truth

The Devices-page SNMP badge is lifted from the engine's real SNMP_Availability result every sync — not from whether someone opened a modal or which plan the company is on.

Reaches private networks

Private targets are polled from the server's site-tunnel address, or through the device's SSH jump host when its Monitoring Route names one — the same route its ping takes. Test SNMP and discovery follow it too.

How it goes live

  1. Enable SNMP on the device, read-only. Edit Device → SNMP → Setup guide shows vendor steps and CLI for 19 platforms (FortiGate, Cisco IOS / ASA, Meraki, UniFi, pfSense, SonicWall, Palo Alto, Aruba, Dell, Juniper, APC, Synology, Windows, Linux, ESXi…) with your values filled in locally.
  2. Allow the SmartTile poller address. The same guide names the exact source IP this device will be polled from for its Monitoring Route (public, forced anchor, site tunnel, or jump host).
  3. Save the credential in SmartTile. Tick SNMP Monitoring, pick v2c (community) or v3 (user, level, auth / privacy protocol and keys).
  4. Test SNMP, then Discover Interfaces. Test returns sysName, sysDescr and uptime; discovery saves the ports to poll and triggers an identity read.
What you giveWhat works
v2c read-only communityEverything on this page.
SNMPv3 user (authPriv recommended)The same, authenticated and encrypted on the wire. Levels noAuthNoPriv, authNoPriv, authPriv.
Device Health on the planHealth sensors and vendor OIDs in the Device Health panel; scheduled health tickets are a separate switch, off by default.
Bandwidth Trigger on the device60-second SNMP sampling and threshold tickets for that circuit.
SmartChoice · SmartTile DeviceAutomate™ — SNMP v2c / v3Page 1 of 2
SMARTTILE · DEVICEAUTOMATE™ · SNMP V2C / V3 — WHAT HAPPENS WHEN THE AGENT GOES QUIET, AND EXACTLY WHAT SMARTTILE ASKS IT

When something goes wrong

The momentSNMP aloneWith SmartTile
An SNMP-only switch diesA trap you may never receive; a graph that just stops.sysUpTime fails three polls → DOWN, written to state history; after the ticket gate one ticket opens for the location in Rev.io and the company's connected ITSM system.
A circuit runs hotSomeone notices the graph later.Over the Bandwidth Trigger for the sustain time → a threshold ticket; recovery closes it.
A stack member is swappedSpreadsheet out of date.The next 6-hourly read records the new serial; a manual value is kept and the disagreement is shown.
The credential is wrongSilent gaps.The badge reads “no reply” from the real poll, and Test SNMP says what failed.

Exactly what SmartTile asks the agent (all reads)

SNMPGET 1.3.6.1.2.1.1.3.0sysUpTime — availability / host check
SNMPGET 1.3.6.1.2.1.2.2.1.8.<if>ifOperStatus per interface
SNMPGET 1.3.6.1.2.1.31.1.1.1.6 / .10ifHCIn / OutOctets → Mbps
SNMPGET 1.3.6.1.2.1.2.2.1.5ifSpeed → utilisation
SNMPGET 1.3.6.1.2.1.2.2.1.13/14/19/20discards and errors, in / out
SNMPGET 1.3.6.1.2.1.1.1 / .2 / .5sysDescr, sysObjectID, sysName
SNMPWALK 1.3.6.1.2.1.47.1.1.1.1ENTITY-MIB: model, serial, firmware
SNMPWALK 1.3.6.1.2.1.25.2 / 25.3HOST-RESOURCES: CPU, memory, disk
SNMPWALK 1.3.6.1.2.1.99.1.1.1ENTITY-SENSOR: temperature, fan, PSU
SNMPGET 1.3.6.1.2.1.33.1.*UPS-MIB: battery, runtime, load

Security and control

Read-only, always

GET, GETBULK and walk only. No SET is implemented anywhere in the SNMP path.

Keys never shown again

Community strings and v3 auth / privacy keys are encrypted at rest; the form shows “Saved — type to replace”, never the value, and they are masked in the audit log by field-name pattern.

Your devices, your company

Test, discovery and graphs check the device belongs to the signed-in user's locations. Each company's credentials stay on its own devices.

Switches you control

SNMP identity, the setup guide, the SNMP host check, jump-host SNMP and the Nagios-driven badge each have their own switch — instant rollback, no redeploy.

Common objections

ObjectionAnswer
“SNMP v2c is clear-text.”Use SNMPv3 authPriv — SHA-256 and AES-256 are offered and recommended in the form.
“Our ACLs only allow one address.”The setup guide prints the exact source address for that device's route; private sites can be polled through a jump host already in your ACL.
“We already graph interfaces elsewhere.”SmartTile puts the same counters next to the circuit, the ticket and the uptime report — and opens the ticket when the agent goes silent.
One read-only credential, and a device with no API reports DOWN, fills in its own identity and graphs its links.