SmartTile reads every WattBox outlet, knows which one powers the modem, fiber box and firewall, and power-cycles them in the right order — when you press the button, when the carrier asks for a reboot, or automatically during an outage. Set up per company, site or device.
Half of all carrier repair calls start with “have you power-cycled the modem?” — and the answer usually means a drive to the site or a call to a store manager. With a WattBox at the site, SmartTile does it remotely: it confirms the equipment has power, restarts the fiber box or modem and then the firewall in the right order, checks whether the site came back, and lets Joey tell the carrier it is done.
On/off, outlet names, watts, volts and amps per outlet where the model meters them, total load and the UPS battery (charge, runtime, mains lost) — read every 5 minutes and kept.
Each outlet mapped to the fiber box / ONT, modem, firewall or switch it powers, with a chain order — fiber box or modem first, firewall second.
Before and during a carrier call SmartTile confirms the equipment has power from its WattBox outlet, so Joey answers the carrier with a fact, never a guess.
The carrier asks Joey for a reboot: SmartTile power-cycles the mapped outlets itself, then records the power-cycle on the carrier ticket so Joey can say it was done.
Optional: when the equipment is confirmed down for the time you choose and the WattBox still answers, SmartTile power-cycles once per outage and checks again.
An admin power-cycles an outlet or the whole chain from the WattBox window, with a confirmation that shows exactly what will be sent.
Equipment that was up is held from alerting until the check-again time; equipment that was already down keeps its DOWN and UP alerts.
Plans, dry runs, power-cycles, results and setting changes are in the PowerAutomate log and the Automation Audit Ledger.
| Option | Default |
|---|---|
| PowerAutomate on (company · site · device) | Off. |
| Power check | On (read-only). |
| Reboot when the carrier asks | Off. |
| Reboot automatically during an outage | Off; 10 minutes down first. |
| Dry run for automatic reboots | On. |
| Cooldown · daily limit | 60 minutes · 2 per day. |
The WattBox password is sealed with AES-256-GCM to its device the moment it is saved; SmartTile shows only “saved”.
Every reboot reads the WattBox first; if it does not answer, nothing is sent and the log says why.
Every option per company, site or device, each showing where its value comes from; admins only for any switch; a platform kill switch for automatic reboots.
An outlet can only be mapped to equipment of the WattBox's own company; every action and setting change is in the ledger.
| Question | Answer |
|---|---|
| “The WattBox is behind the firewall that went down.” | Then no remote system can reach it. SmartTile says so in the log; the WattBox's own auto-reboot — shown and switchable in its SmartTile window — is the fallback. |
| “Do you go through OvrC?” | No. SmartTile talks to the WattBox directly, so it works whatever happens to the OvrC account. |
| “Will a planned reboot send alerts?” | Not for equipment that was up — it is held until SmartTile checks again. A real outage always keeps its alerts. |